Drager Babylog 8000 Plus Ventilator
If you are looking critical care medical equipment, then just visit Outfront Medical. We are your one-stop place to buy, sell and rent refurbished medical equipment at great prices.contact us at 609-388-4635 to know prices.
The Babylog 8000 plus is designed for harmonious ventilation of small children and the smallest pre-term babies. It has an advanced upgrade platform that has allowed it to keep pace with all new forms of treatment and clinical advances.
Sensitive synchronisation with gentle but precise support for spontaneous breathing reduces the work of breathing and makes the ventilation process much more comfortable for patients.
Product Description
The Babylog 8000 plus is designed for harmonious ventilation of small children and the smallest pre-term babies. It has an advanced upgrade platform that has allowed it to keep pace with all new forms of treatment and clinical advances.
Sensitive synchronisation with gentle but precise support for spontaneous breathing reduces the work of breathing and makes the ventilation process much more comfortable for patients.
TECHNICAL SPECIFICATIONS:
Controls
Conventional ventilation: continuous flow, pressure-limited, time-cycled
Triggered ventilation: SIMV, SIPPV, PSV1), leak adapted- Trigger: Flow/volume trigger, leak adapted- Trigger delay: approx. 40-60 ms
High Frequency Ventilation: CPAP+HFV, IMV+HFV- Frequency: 5 to 20 Hz
Volume Guarantee Ventilation: SIMV+VG, SIPPV+VG, PSV+VG
Oxygen mixer loss (bleed flow): 0 (zero) L/min
Settings
Inspiratory oxygen concentration: 21-100 vol.% oxygen
Peak inspiratory pressure: 10 to 80 mbar
PEEP/CPAP: 0 to 25 mbar
Maximal frequency: 200 bpm
Inspiratory time: 0.1 to 2 seconds
Expiratory time: 0.2 to 30 seconds
Inspiratory flow: 1 to 30 L/min
Base Flow (VIVE): 1 to 30 L/min
Monitoring
Flow monitoring: at the Y-piece, integrated
Volume monitoring: at the Y-piece, integrated
Lung function monitoring: compliance, resistance C20/C
Method: linear regression analysis
FiO2 monitoring: integrated
Real-time curves: Flow and pressure, integrated
Inspiratory oxygen concentration: 21-100 vol.% oxygen
Peak pressure: to 99 mbar
Mean airway pressure: to 99 mbar
Graphic trends: 6 parameters, integrated
Logbook: record of up to 100 alarms
Dräger Babylog® VN600
Model Babylog 8000 Plus. P/n 8410280. Item is not functioning as specified and the item is not sold As Is. for example, the condition specified is
Drager Babylog 8000 Plus Ventilator 8410280
Babylog® 8000 plus
Refurbhised Drager Babylog 8000 plus - Hospital ventilator
Drager Babylog 8000 Ventilator – MedGill Ltd
Dräger Babylog 8000 Plus The Drager Babylog 8000 plus offers Non-invasive respiratory support for Neonatal patients, including premature babies,
Used DRAGER BABYLOG 8000 Plus Ventilator For Sale - DOTmed Listing #4559468
Drager Babylog 8000 External Display
Babylog® 8000 plus
Drager Babylog 8000 Plus Ventilator Ref 8409200-45 on Stand
Dräger Babylog 8000 Plus 8410280-38, Ventilator, Product Details, Opt. SW 5.01 LFT, 45033 Hours of operation, MFG 2009, Includes Advantech POC-123v2
Dräger Babylog 8000 Plus 8410280-38 Ventilator with Computer / Monitor
Drager Babylog 8000 Plus Ventilator Featuring Optimal Levels of
Used DRAEGER BABYLOG 8000 Plus Ventilator For Sale - DOTmed
Dräger Babylog 8000 Ventilator
Used DRAEGER Babylog 8000 Plus with Graphics Ventilator For Sale